THREE-PHASE ELECTRIC ENERGY METER SEA3.

SEA3 SEA3 SEA3М SEA3М
  • Three-phase electric energy meter SEA3 is an electrotechnical product, analog-digital devise that sums and indicates on electromechanical reading device the quantity of electric energy meter input in kWt/h.
    General purpose
  • Measuring of active electric energy by one or two rates in tree- or four-wire three-phase circuits directly or through measuring current and voltage transformers, autonomously or amounting to information and metering systems as a sensor of energy increment and power measuring.
    Standard provision
  • The meters are developed and go into series production according to the requirements of Quality standard ISO 9001 (GOST R ISO 9001-2001), correspond to technical specifications IZHSK. 411152.003 TU, GOST 30207-94 “Static meters of active energy Watt-hours of alternating current (accuracy class 1-2)”, safety requirements determined by GOST R 51350-99. The meters are included in public register of measurement instrumentation in Russia, reference No18264-04, and several countries of the CIS. The meter is certified. Certificate of conformance No 6526270.
    Features
  • The meters are made on the basis of specialized microcircuit by means of surface mounting technology.
  • The meters have large technological margin on accuracy class.
  • Stable to mechanical and climatic influence.
  • Stable to fails and short breaks of mains supply voltage.
  • The meters correspond to the requirements to products on electromagnetic compatibility.
  • The meters are protected from shunt running and influence of constant and alternating external electromagnetic fields.
  • The meters have impulse telemetering output and indicator lamp that operates as indicator of voltage presence in the circuit as well as indicator of a consumer’s load.
  • Double-rate modification has an input for switching the tariff.
    Reliability characteristics
  • Mean time to failure – 72000 hours.
  • Mean lifetime – 25 years.
  • Warranty lifetime – 18 months.
  • Calibration interval – 6 years.
    Construction
  • The meter is made in a plastic case, protection from dust and water penetration - IP 51. The case comprises a meter block consisting of terminal block with two or three measuring current transformers, printed-circuit board with surface and volumetric mounting of electronic components and reading devise. Terminal block has a sealed lid. Meter case is sealed by the division of technical control of the manufacturing plant and by a state officer.
    Modifications
    Name Modification Accuracy class Type of reading device indicator Way of switching summators of tariff II into active state (for double-rate meters)
    1 SEA3-1 5-55A Single-rate of direct connection 2 Mechanical  
    2 SEA3М-1 5-55А*
    3 SEA3М-1 5-55А 1,0* 1
    4 SEA3МI-1 5-55А 1,0* LCD
    5 SEA3-1 10-100А 2 Mechanical
    6 SEA3-1 1-8А Single-rate, connected through measuring current transformers
    7 SEA3М-1 1-8А*
    8 SEA3М-1 1-8А 1,0* 1
    9 SEA3МI-1 1-8А 1,0* LCD
    10 SEAМТ-1 1-8А* Single-rate, connected through measuring current and voltage transformers 2 Mechanical
    11 SEA3МТ-1 1-8А 1,0* 1
    12 SEA3МТI-1 1-8А 1,0* LCD
    13 SEA3МУ-1 1-8А 1,0* Mechanical
    14 SEA3МUI-1 1-8А 1,0* LCD
    15 SEA3-2 5-55А Double-rate of direct connection 2 Mechanical Tariffs can be switched by means of any external tarifficator ensuring control voltage supply of the required value (~220 V, frequency 50 Hz or +12 V of direct current).
    16 SEA3М-2 5-55А*
    17 SEA3-2 10-100А
    18 SEA3МI-2 5-55А 1,0* 1 LCD
    19 SEA3-2 1-8А Double-rate, connected through measuring current and voltage transformers 2 Mechanical
    20 SEA3М-2 1-8А*
    21 SEA3МI-2 1-8А 1,0 1 LCD
    22 SEA3МТ-2 1-8А* 2 Mechanical
    23 SEA3МТИ-2 1-8А* 1,0* 1 LCD
    24 SEA3МУ-2 1-8А* 2 Mechanical
    25 SEA3МUI-2 1-8А 1,0* 1 LCD
    * designed in a small-size case.
    ** double-rate meters in which summators are switched by means of  direct current, in the end of its name index +12V is added
    Технические характеристики

    Parameters name Parameters value
    Rated voltage, V 3х220/280 with 1 - 16 pos., 3х57,7/100 with 17 - 21 pos., 3х100 with 22 - 25 pos.
    Rated (maximum) current, A 5(55) with 1 - 7 pos., 10(100) with 8 - 9 pos., 1(8) with 10 - 25 pos.
    Frequency of measuring circuit, Hz 50±2,5
    Established voltage working range, V 198-242 with 1 - 16 pos., 52-63,5 with 17 - 21 pos., 90-110 with 22 - 25 pos.
    Limiting voltage working range, V 176-253 with 1 - 16 pos., 46-66,4 with 17 - 21 pos., 80-115 with 22 - 25 pos
    Range of measured currents, A 0,5-55 with 1-7 pos., 1-100 with 8-9 pos., 0,1-8 with 10 по 25 pos.
    Threshold of sensitivity, Wt, not more than 16,5 with 1-7 pos., 33 with 8-9 pos., 3,3 with 10 по 16 pos., 0,9 with 17 - 25 pos.
    Gear-ratio of transmitting terminal, imp./ kWt.h 1600 with 1 - 9 pos., 16000 with 10 - 25 pos.
    Weight, kg, not more than 2


    Marks of clips and schemes of inclusion of counters
    the Scheme of inclusion of counter SEA3
    direct inclusion
    the Scheme of inclusion of counter SEA3
    transformer inclusion on a current

    The scheme of inclusion of three-wire counters SEA3MU of transformer inclusion on a current and a pressure

    The scheme of direct connection of meters SEA3M

    The scheme of direct connection of meters SEA3M
    transformer inclusion on a current
    The scheme of connection of four-wire meters SEA3MT of transformer inclusion on a current and a pressure
    Overall and mounting dimensions of meters SEA3


    Overall and mounting dimensions of meters SEA3M



  •   Copyright © 2007-2011 JSC "Signal" Webmaster Vitaly Zarvirov  
    герб ссср . Наушники с: микронаушник для экзамена. Наушники Ritmix RH-701. . посмотрите, здесь перевозки газель . Гарантия, светильник точечный цена.