AUTOMATIC LIGHTING SWITCH AVO

Automatic switch of illumination Purpose
  • For smooth inclusion and deenergizing of illumination ladder ploshchadok inhabited and office buildings, individual cottages and country houses depending on natural light exposure.
    normative maintenance
  • AVO corresponds to specifications IJSK.648342.001TU "Automatic switches of illumination" and to the obligatory requirements established by GOST R 513224.2.1-99. A degree of protection for the operative panel of electronic block AVO-IP30; for the remote gauge - IP54.
  • QF1, QF2 - automatic switches correspond to GOST R 50345.
    Features
  • Are maintained nekvalifitsirovannym and have a design consisting of the electronic block and the remote gauge, not demanding technical and operating repair.
    characteristics of reliability
  • Average service life - 10 years.
  • a warranty period of operation - 2 years.
    the design
  • AVO consists of the electronic block and the remote gauge with a connecting cable. The electronic block includes two unipolar switches, one of which makes management of illumination in a manual mode, by another - in automatic, connected with the module in which the printed-circuit-board of the electronic scheme of management is placed. On the operative panel of the electronic block are placed: the handle of the variable resistor for an establishment of a threshold of operation, the switch of a choice of time of transition in an economic mode of illumination and the indicator of operating modes.
    Principles of work
  • Work of the switch of illumination in an automatic mode is based on change of size of the current proceeding through the photoresistor of the gauge depending on natural light exposure. With approach of twilight resistance of the photoresistor increases, the current decreases, and at achievement of the certain size the controller submits a signal on inclusion of a network of a feed of lamps. With approach of twilight resistance of the photoresistor increases, the current decreases, and at achievement of the certain size the controller submits a signal on inclusion of a network of a feed of lamps of illumination. With increase in light exposure resistance of the photoresistor decreases, that leads to switching-off of lamps of illumination. Management of illumination in a manual mode is carried out by the switch of manual management, thus the switch of automatic control should be switched off (in position "0"). In a mode of automatic control of illumination the switch of manual management should be in the switched off condition (in position "0"), and the switch of automatic control by a mode of illumination - in position is included (in position "I").
    Structure of a symbol
    Tipoispolnenija
    ¹ Tipoispolnenija Switch for manual management of illumination
    1.ÀÂÎ1-750-0 UXL4 +
    2. ÀÂÎ1-750-1 UXL4-
    Note: Electric parameters of the device can be changed at will of the customer.
    Characteristics
    Name of parameter Value
    CeA1-750-0 CeA1-750-1
    Rated voltage Un, In 220
    Nominal frequency, Hz 50
    Rated load, Vt 750
    Minimal loading, Vt 40
    Power consumption at a pressure 220e, no more, VA 5
    Limits of regulation of sensitivity, The personal computer 2-200
    Time of a delay of inclusion and deenergizing not less, sek. 40
    Time of transition in an economical mode after inclusion through, hour 3/5
    Section of a connected wire, mm2 1-2,5
    Length of a connecting cable of the remote gauge, no more, than m 50
    Average service life, years 10
    Note: Electric parameters of the device can be changed at will of the customer.
    Conditions of operation
  • AVO provide reliable and steady work during influence of climatic factors, characteristic for areas with the moderate and cold climate:
    - a range of working temperatures of the electronic block - from a minus 10°Ñ up to +40°Ñ;
    - the remote gauge - from a minus 40°Ñ up to +40°Ñ.
  • the Degree of protection for the operative panel of electronic block AVO - IP30; for the remote gauge - IP54.
    the Scheme of connection
    À1 - the electronic block:
    QF1 - for automatic control of illumination;
    QF2 - the switch for manual management of illumination;
    À2 - the remote gauge;
    HL1 … HLn - lamps nakalivanija.

    The Dimensional, adjusting sizes and weight
    Overall dimensions and weight
    IJSK.648342.001-01
    Weight no more than 0,5 kg Weight no more than 0,35 kg


    Weight no more than 0,15 kg
    The Designation of products at the order
  • AVO with the switch for manual management of illumination:
    ÀÂÎ1-750-0 UXL4 IJSK.648342.001TU.
    Completeness of delivery
    ¹ ï/ïDesignation NameQuantity
    1IJSC.648342.001ÒÓElectronic block 1
    2 Remote gauge with a connecting cable  
    3 Operation manual 